How to Specify a PTFE-Lined Tee Branch
Label the two run connections and the branch. State whether the branch matches the main bore and provide an orientation view when the tee forms part of a vertical or skewed assembly.
Dimensions and service inputs
Check center-to-face dimensions and access to the fasteners at all ends. Near pumps or instruments, use a drawing to check space for mating equipment and service access.
Before issuing the RFQ
Specify the wetted liner material and the metal shell separately. Ask for a sectional or dimensional drawing before accepting a substitute branch detail.
Separate branch size from the installed bore
A branch nozzle may carry the same nominal size as the old line while the installed liner reduces its clear opening. If an instrument or insert passes into the branch, include its required envelope and the actual opening needed.
Related products
Related information
- PTFE-Lined Tees
- PTFE-Lined Pipe Spools
- Request a project quotation
- Technical resources
- Specifying Lined Branch Connections in Chlor-Alkali Service
Discuss your application
Send the medium, operating conditions and mating dimensions for the parts under review. If the project is a replacement, include the existing equipment tag and drawing revision.