Specifying Corrosion-Resistant Equipment for Wastewater Dosing

A wastewater dosing station may have a concentrated chemical tank, a diluted day tank and small pressurized transfer lines. Capture each dosing chemical, concentration and exposure separately. Include any cleaning fluid and capture credible changes caused by the filling arrangement.

Industrial water-treatment equipment in a process room
Industry context: Industrial water-treatment equipment in a process room

Equipment and lining options

PE, PP and other plastic linings must be reviewed by resin and service rather than by appearance. A rubber-lined tank can be considered for compatible service. Flanged PTFE-lined steel pipe can be reviewed where interface stiffness and chemical duty call for it.

Steel tank opening with polyethylene lining
Illustrative PE-lined steel opening. See the manufacturing catalogue details for the rotolined configuration.

What to include in an RFQ

Provide working volumes, fill and overflow details, nozzle elevations, available space and the piping layout. Identify how the equipment will be isolated and drained for maintenance.

Discuss your application

Send the medium, operating conditions and mating dimensions for the parts under review. If the project is a replacement, include the existing equipment tag and drawing revision.